Braz. j. oral sci ; 18: e191620, jan.-dez. 2019. ilus
Article in English | LILACS, BBO | ID: biblio-1095173

ABSTRACT

Aim: it was to use tridimensional finite element analysis (FEA) to analyze the effect of height and angulation of prosthetic preparations on the distribution of stresses for lithium disilicate prosthetic crowns, the underlying resin cement, and the prosthetic preparation of a superior central incisor. Methods: a CAD modeling software, SolidWorks 2013, was used to generate three-dimensional virtual models comprising the dimensions of the preparation parameters. Three angles (6, 12 and 16 degrees) were simulated on the prepared walls and two wall heights were utilized (4 and 5 mm), for a total of six model groups according to the height and angulation of the walls. A vertical line in the Y-axis was used as a reference for determining the degrees of convergence (inclination of the preparations). The chamfer finish and preparation width were standardized for all groups. Results: the 4 mm preparations behaved more appropriately when the axial wall convergence was approximately 6 degrees. The 5 mm preparations required 12 degrees of angulation. In relation to resin cement, there was better stress distribution when the angle of incisal convergence was between 6 and 12 degrees. An increase to 16 degrees led to a considerable increase in peak stress at the preparation margin. Conclusion: it was concluded that the convergence of the axial walls of coronal preparations with 4 and 5 mm heights should be 6 and 12 degrees, respectively, to avoid high tension spikes in the underlying resin cement


Subject(s)
Dental Prosthesis , Tooth Preparation , Finite Element Analysis , Incisor
2.
Rev. odontol. UNESP (Online) ; 47(4): 223-229, jul.-ago. 2018. ilus
Article in English | LILACS, BBO | ID: biblio-961528

ABSTRACT

Introduction: A better tension distribution on implants and abutments in implant-supported fixed partial prosthesis is essential in the rehabilitation of posterior mandible area. Objective: To evaluate the influence of cantilever position and implant connection in a zircônia custom implant-supported fixed partial prosthesis using the 3-D finite element method. Material and method: Four models were made based on tomographic slices of the posterior mandible with a zirconia custom three-fixed screw-retained partial prosthesis. The investigated factors of the in silico study were: cantilever position (mesial or distal) and implant connection (external hexagon or morse taper). 100 N vertical load to premolar and 300 N to molar were used to simulate the occlusal force in each model to evaluate the distribution of stresses in implants, abutments, screws and cortical and cancellous bone. Result: The external hexagon (EH) connection showed higher cortical compression stress when compared to the morse taper (MT). For both connections, the molar cantilever position had the highest cortical compression. The maximum stress peak concentration was located at the cervical bone in contact with the threads of the first implant. The prosthetic and abutment screws associated with the molar cantilevers showed the highest stress concentration, especially with the EH connection. Conclusion: Morse taper implant connetions associated with a mesial cantilever showed a more favorable treatment option for posterior mandible rehabilitation.


Introdução: Uma melhor distribuição de tensão em implantes e mini-pilares em próteses parciais fixas implanto-suportadas é essencial na reabilitação em região posterior de mandíbula. Objetivo: Avaliar a influência da posição do cantilever e conexão do implante em uma prótese fixa de três elementos confeccionada totalmente em zircônia através do método de elementos finitos tridimensionais (MEF). Material e método: Foram confeccionados quatro modelos baseados em cortes tomográficos da região posterior da mandíbula com uma prótese parcial parafusada fixada em três fixações personalizadas de zircônia. Os fatores investigados do estudo in sílico foram: posição do cantilever (mesial ou distal) e conexão do implante (hexágono externo ou cone morse). Uma carga de 100 N para a região de pré-molares e de 300 N para a região de molares foi usada para simular a força oclusal em cada modelo para avaliação da distribuição de tensões nos implantes, mini pilares, parafusos e tecido ósseo cortical e medular. Resultado: A conexão hexágono externo apresentou maior concentração de tensão no osso cortical quando comparado ao cone morse. Para ambas conexões, o cantilever distal aumentou a tensão no osso cortical. O pico máximo de tensão foi localizado no osso cervical em contato com as primeiras roscas internas do primeiro implante. Os parafusos protéticos e dos mini-pilares associados ao cantilever distal apresentaram maior concentração de tensão, especialmente na conexão hexágono externo. Conclusão: Conexão do implante cone morse associada ao cantilever mesial apresentou uma opção de tratamento mais favorável para a reabilitação na região posterior de mandíbula.


Subject(s)
Zirconium , Finite Element Analysis , Dental Implantation , Denture, Partial, Fixed , Mandible
3.
Einstein (Säo Paulo) ; 16(3): eRC4003, 2018. graf
Article in English | LILACS | ID: biblio-953172

ABSTRACT

ABSTRACT Juvenile idiopathic arthritis is a term used to include all chronic childhood arthritis of unknown etiology. It is characterized by chronic inflammation persisting for at least 6 weeks, beginning before 16 years of age. The characteristics present are chronic synovitis, arthralgia, impaired joint mobility in at least one joint, and erosion with destruction of cartilage and subchondral bone, that could be associated or not with systemic involvement, according to each subtype of the disease. During the pathologic process, the temporomandibular joint can be involved by the juvenile idiopathic arthritis, resulting in severe mandibular dysfunction, with higher frequency in female patients. Initially, these lesions can show minor alterations like flattening of the condyle, erosions, and evolve to severe lesions, like destruction of the head of the condyle. We report a case of male patient who had destruction of both condyles, as a result from juvenile idiopathic arthritis. Proposed mechanisms to explain the juvenile idiopathic arthritis was reviewed. In this report the patient did not have pain or inflammatory process, and the temporomandibular diseases was the only manifestation.


RESUMO Artrite idiopática juvenil é um termo usado para incluir toda artrite infantil crônica de etiologia desconhecida. É caracterizada por uma inflamação crônica, que persiste por pelo menos 6 semanas, com início antes dos 16 anos de idade. As características presentes são sinovite crônica, artralgia, mobilidade articular diminuída em pelo menos uma articulação, e erosão com destruição da cartilagem e do osso subcondral, podendo ser associada ou não com o envolvimento sistêmico, de acordo com cada subtipo da doença. Durante o processo patológico, a articulação temporomandibular pode ser envolvida pela artrite idiopática juvenil, resultando em disfunção mandibular severa, com maior frequência em pacientes do sexo feminino. Inicialmente, estas lesões podem mostrar pequenas alterações, como achatamento do côndilo e erosões, e evoluir para lesões graves, como a destruição da cabeça do côndilo. Relatou-se o caso de um paciente do sexo masculino, que apresentou destruição de ambos os côndilos, como resultado da artrite idiopática juvenil. Os mecanismos para explicar a artrite idiopática juvenil foram revisados na literatura. Neste relato de caso, o paciente não apresentou dor e nem processo inflamatório, sendo o comprometimento da articulação temporomandibular a única manifestação.


Subject(s)
Humans , Male , Child , Arthritis, Juvenile/complications , Temporomandibular Joint Disorders/etiology , Temporomandibular Joint Disorders/diagnostic imaging , Arthritis, Juvenile/pathology , Radiography, Panoramic , Temporomandibular Joint Disorders/pathology , Tomography, X-Ray Computed
4.
Braz. dent. sci ; 21(1): 37-43, 2018. ilus, tab
Article in English | LILACS, BBO | ID: biblio-881830

ABSTRACT

Objective: The aim of this study was to evaluate dimensional stability and detail reproduction in alginate molds stored at different times and temperatures. Material and Methods: Three different commercially available alginates (Cavex Color Change, Jeltrate Plus and Hydrogum 5) were tested at four different times (0 - control, 1, 3 and 5 days) and two temperatures (25ºC and 37ºC) (n=5). The alginates were handled following the manufacturer's instructions. The impression procedures occurred in an environment with controlled room temperature (25ºC) and relative humidity (50±5%). A metallic model (ISO 1563:1990) was used to perform the impressions. The tray containing alginate remained on the metallic model under constant pressure (2 kgf) until the alginate gelation process. The molds were stored (different times and temperatures) and analyzed in stereomicroscope at 30x magnification and 0.5 µm accuracy (Olympus Measuring Microscope STM). The molds and the metallic model measurements were compared, and the data were statistically analyzed by Kolmogorov-Smirnov and three-way ANOVA tests, and the means were compared by Tukey test (5%). Results: The results showed no double interactions (p>0.05) and the different alginates presented statistically similar values of dimensional stability (p=0.102). However, 25ºC (temperature) and control group (time) showed the highest values of dimensional stability (p <0.05). Jeltrate Plus was the only material that presented inaccuracy in details reproduction. Conclusion: It is recommended that, for tested alginates, the stone casts should be poured immediately, even though the molds are dimensionally stable up to 5 days when stored at 25ºC.(AU)


Objetivo: O objetivo neste estudo foi avaliar a estabilidade dimensional e a reprodução de detalhes em moldes de alginatos armazenados em diferentes tempos e temperaturas. Material e Métodos: Foram testadas três diferentes marcas de alginato (Cavex ColorChange, Jeltrate Plus e Hydrogum 5), sendo que esses materiais foram armazenados por quatro diferentes tempos (0 - controle, 1, 3 e 5 dias) e duas diferentes temperaturas (25ºC e 37ºC) (n=5). Os alginatos foram manipulados seguindo as instruções do fabricante. A moldagem ocorreu em um ambiente com temperatura (25ºC) e umidade relativa (50±5%) controladas. Foi utilizado um modelo metálico (ISO 1563:1990) para a realização das moldagens. A moldeira contendo o alginato permaneceu sobre o modelo metálico sob pressão constante de 2 kgf até a geleificação do material. Em seguida, os moldes foram armazenados nos tempos e temperaturas testados, sendo posteriormente avaliados sob um microscópio comparador (Olympus Measuring Microscope STM) com precisão de 0,5 µm. As medidas dos moldes de alginato foram comparadas com as medidas do modelo metálico padrão, sendo os dados analisados estatisticamente pelos testes de Kolmogorov-Smirnov e ANOVA três fatores, sendo as médias foram comparadas pelo teste de Tukey (5%). Resultados: Os resultados mostraram nenhuma interação dupla (p>0,05), sendo que os diferentes alginatos apresentaram valores de estabilidade dimensional estatisticamente semelhantes entre si (p=0,102). Já a temperatura de 25ºC e o grupo controle (tempo) mostraram os maiores valores de estabilidade dimensional (p <0,05). O Jeltrate Plus foi o único material que apresentou imprecisão na reprodução de detalhes. Conclusão: Recomenda-se que os alginatos testados tenham os modelos de gesso vazados imediatamente, apesar dos moldes serem dimensionalmente estáveis até 5 dias desde que armazenados a 25ºC. (AU)


Subject(s)
Dental Impression Materials , Dimensional Measurement Accuracy
5.
ImplantNewsPerio ; 2(5): 861-866, set.-out. 2017. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-877279

ABSTRACT

Objetivo: avaliar a resistência à tração de copings fundidos cimentados sobre pilares cone-morse com diferentes alturas e diâmetros. Material e métodos: quatro grupos (G1: 3,5 mm x 4 mm; G2: 3,5 mm x 6 mm; G3: 4,5 mm x 4 mm; e G4: 4,5 mm x 6 mm) com cinco amostras cada tiveram seus copings encerados, fundidos (liga de Ni-Cr) e cimentados (Panavia F, carga de 6 Kfg durante cinco minutos) sobre os respectivos pilares já torqueados com 25 Ncm. Depois, as amostras foram imersas em água destilada a 37oC ± 2oC durante 24 horas e submetidas ao ensaio de tração até soltura das restaurações. Os dados obtidos foram analisados estatisticamente quanto ao atendimento das pressuposições de normalidade e de homogeneidade de variância, pelos testes de Shapiro-Wilk, Levene e Anova dois critérios (α=5%). Resultados: os valores (média ± desvio-padrão) de resistência à tração (em Newtons) foram: G1: 108,9 ± 37,2; G2: 168,6 ± 43,9; G3: 143,4 ± 57,1; G4: 236,8 ± 52,2. Não houve interação estatisticamente significativa entre as variáveis diâmetro e altura (p=0,446). Ao se comparar os valores de resistência à tração, notou-se efeitos estatisticamente significativos entre o diâmetro (p=0,030) e a altura (p=0,003) dos munhões cone-morse. Munhões com 4,5 mm de diâmetro proporcionaram resistência à tração significativamente superior àquela obtida na condição em que foram empregados munhões com 3,5 mm, tanto nas condições 4 mm quanto 6 mm de altura. A resistência à tração foi aumentada (37%) com munhões 4,5 mm comparados aos munhões 3,5 mm. A resistência à tração foi aumentada (60,7%) com a altura de 6 mm, comparada à altura de 4 mm. Conclusão: pilares para implantes cone-morse com maiores dimensões proporcionam maior segurança e estabilidade às coroas cimentadas sobre implantes.


Objective: to evaluate the tensile strength of cemented copings on cone-morse abutments with different heights and diameters. Material and methods: four groups (G1: 3.5 mm x 4 mm; G2: 3.5 mm x 6 mm; G3: 4.5 mm x 4 mm; and G4: 4.5 mm x 6 mm) with five samples each had their waxed copings and cast in Ni-Cr alloy, being cemented (Panavia F, 6 Kgf-load, 5 minutes) on their respective already torqued abutments (25 Ncm). Then, samples were immersed in distilled water (37oC ± 2oC) for 24 hours and subjected to the tensile test until restorations being separated. The data obtained were analyzed statistically for normality and homogeneity of variances by the Shapiro-Wilk and Levene tests. Comparisons were made using the 2-way Anova test (α=5%). Results: the values (mean ± standard deviation) of tensile strength (in Newtons) were: G1: 108.9 ± 37.2; G2: 168.6 ± 43.9; G3: 143.4 ± 57.1; G4: 236.8 ± 52.2. There was no statistically significant interaction between the variables diameter and height (p=0.446). When comparing values of tensile strength, we observed statistically significant effects for diameter (p=0.030) and height (p=0.003). Abutments with a 4.5 mm diameter provide significantly higher tensile strength to those obtained with 3.5 mm in both 4 mm and 6 mm height conditions. The tensile strength was increased (37%) for the 4.5 mm compared to the 3.5 mm condition. The tensile strength was increased (60.7%) with a height of 6 mm, compared to height of 4 mm. Conclusion: abutments for cone-morse implants with larger dimensions provide greater safety and stability for cemented crowns.


Subject(s)
Humans , Data Interpretation, Statistical , Dental Casting Technique , Dental Implantation , Osseointegration , Tensile Strength
6.
RGO (Porto Alegre) ; 65(2): 151-155, Apr.-June 2017. graf
Article in English | LILACS, BBO | ID: biblio-896004

ABSTRACT

ABSTRACT Temporomandibular disorder (TMD) may be defined as a set of clinical scenarios involving the masticatory muscles, the temporomandibular joint (TMJ) and associated structures. Currently, 40 to 75% of the population has some sign of temporomandibular disorder, mainly pain located in the muscles of mastication in the pre-auricular region. The present clinical case was diagnosed as muscle temporomandibular disorder secondary to parafunction, as well as muscle hyperactivity due to surgical displacement of the left temporal muscle on two occasions, one for placement of aneurysm clips and the other for tumor excision from the supraorbital region on the left side. The patient sought medical and dental attention for 10 years due to constant headaches, tiredness and pain in the cheeks. The patient tried numerous bite-guards and pharmacological therapies to no avail. The American Academy of Orofacial Pain Questionnaire was applied combined with the Criteria for Research and Diagnostics (DRC) and a decision was made to use botulinum toxin type A in the masseter and temporalis muscles. An analog pain scale was applied over 90 days. Three days following the application of botulinum toxin type A, the patient reported a significant improvement with complete resolution of pain (level 0) after 90 days. At 12 weeks from starting treatment, facial muscle physiotherapy was introduced to strengthen the muscles of mastication and the patient remained pain-free, which allowed the preparation and adaptation of a snap-on prosthetic appliance. In conclusion, the use of botulinum toxin in patients with temporomandibular disorder should be considered as a viable therapeutic option.


RESUMO A desordem temporomandibular pode ser definida como um conjunto de distúrbios que envolvem os músculos mastigatórios, a articulação temporomandibular e estruturas associadas. Atualmente entre 40 a 75% da população apresenta algum sinal de desordem temporomandibular, sendo o mais frequente a dor, principalmente localizada nos músculos da mastigação e na região pré-auricular. O caso clínico apresentado foi diagnosticado como desordem temporomandibular muscular por parafunção, hiperatividade muscular antecedida por deslocamento do músculo temporal esquerdo para realização de duas cirurgias, uma para colocação de clips aneurismático e a outra para remoção de um tumor na região supraorbitária do lado esquerdo. A paciente procurou durante 10 anos ajuda médica e odontológica por sofrer com constantes dores de cabeça, cansaço, dor nas bochechas, usou inúmeras placas, medicamentos, porém o efeito desejado nunca fora alcançado. Frente ao histórico foi aplicado o questionário da Academia Americana de Dor Orofacial e o Critério de Pesquisa e Diagnóstico (RDC), e a conduta clinica adotada foi à aplicação de toxina botulínica tipo A nos músculos masseter e temporal. Foi aplicada uma escala de dor analógica ao longo de 90 dias. Já após 3 dias da aplicação da toxina botulínica tipo A, a paciente relatou melhora significativa chegando a nível 0 de dor após 90 dias. Após 12 semanas do início do tratamento, foram acrescidos exercícios para fortalecimento dos músculos da mastigação, sendo que a paciente continuava sem dor, permitindo desta forma a confecção e instalação de prótese tipo Snap-on. Desta forma, o emprego da toxina botulínica em pacientes com desordem temporomandibular deve ser considerado como uma boa opção terapêutica.

7.
RGO (Porto Alegre) ; 65(1): 25-29, Jan.-Mar. 2017. tab
Article in English | LILACS | ID: biblio-842359

ABSTRACT

ABSTRACT Objective: The purpose of this in vitro study was to assess and compare the dimensional accuracy of three impression techniques: 1-step putty/light-body, 2-step putty/light-body, and the monophase technique. Methods: A partially edentulous standard stainless steel mandibular arch cast with reference points on the teeth was used to make the impressions. The anteroposterior and transverse distances were measured. All impressions were made with a polyvinyl siloxane using stock metallic (1- and 2-step putty/light-body techniques) or acrylic resin (monophase technique) trays. The monophase impressions were made using a light-body material and the 1- and 2-step putty/light-body impressions with putty and light-body materials. After impression procedures, the accuracy of each technique was assessed measuring the stone casts (n = 5) poured from the impressions using a microscope at 30x magnification and at 0.5 µm accuracy. The data were analyzed statistically using 2-way ANOVA and Tukey's test (p<0.05). Results: Stone casts made by all techniques had significantly negative linear changes (shrinkage). The anteroposterior distances showed more dimensional changes than the transverse distances. The edentulous side showed more shrinkage than the anteroposterior side. Conclusion: No differences between the impression techniques were found, but significant dimensional changes were observed.


RESUMO Objetivo: Avaliar e comparar a precisão dimensional de três técnicas de moldagem: dupla mistura, reembasamento e moldeira individual. Métodos: Um modelo metálico inferior parcialmente edêntulo foi fabricado com pontos de referência nos dentes e usado para fazer as moldagens. As distâncias ântero-posteriores e transversais foram medidas. Todas as moldagens foram feitas com um silicone por adição utilizando moldeiras metálicas (técnicas da dupla mistura e reembasamento) ou de resina acrílica (técnica da moldeira individual). Na técnica da moldeira individual foi utilizado apenas o elastômero de viscosidade leve e nas técnicas da dupla mistura e reembasamento foram usados os elastômeros nas viscosidades denso e leve. Após os procedimentos de moldagem, a precisão dimensional de cada técnica de moldagem foi avaliada aferindo os modelos de gesso (n = 5) em um microscópio comparador com 30x de aumento e 0,5 µm de precisão. Os dados foram analisados estatisticamente por ANOVA dois fatores e teste de Tukey (p<0,05). Resultados: Os modelos de gesso feitos com todas as técnicas de moldagem apresentaram alterações lineares negativas (contração). As distâncias ântero-posteriores apresentaram maiores alterações dimensionais que as distâncias transversais. O lado parcialmente edêntulo teve maior contração que o lado ântero-posterior oposto. Conclusão: Não foram encontradas diferenças entre as técnicas de moldagem, mas foram observadas significantes alterações dimensionais.

8.
Rev. odontol. UNESP (Online) ; 45(4): 227-233, July-Aug. 2016. tab, ilus
Article in English | LILACS, BBO | ID: lil-795229

ABSTRACT

Introduction: The correct use of glass fiber posts in endodontically treated teeth is essential for the clinical success of restorative treatment. Objective: This study evaluated the push-out shear bond strength of relined (R) or non-relined (NR) glass fiber posts, cemented with self-adhesive resin cement [RelyXTM U100 (U100)] and conventional resin cement [RelyXTM ARC (ARC)]. Material and method: Sixty human single-rooted teeth were endodontically treated and divided into ARC-NR; U100-NR; ARC-R; U100-R groups. The teeth were sectioned into cervical, middle and apical thirds, and subjected to the push-out test. Bond strength was analyzed by the Friedman test; cement and post types were compared by the Mann Whitney test. The pattern of failures was evaluated with digital camera through images at 200x magnification, and was classified as adhesive (at the cement/dentin or cement/post interface), cohesive (cement or post), and mixed failures. Result: In ARC-NR, bond strength values were higher in the cervical third; in U100-NR and ARC-R they were similar between the thirds. In U100-R, in the cervical and middle thirds the bond strength values were similar, and there was lower value in the apical third. For non-relined glass fiber posts, the highest mean bond strength values were observed with self-adhesive resin cement. Whereas, relined posts cemented with conventional resin cement had stronger cement layer in comparison with non-relined fiber posts. Conclusion: The post relining technique was efficient in ARC-R. ARC-NR and U100-R showed improved bond strength in the cervical region of canal walls. The main failures were adhesive at the cement-post interface.


Introdução: O correto uso de pinos de fibra de vidro em dentes tratados endodonticamente é essencial para o sucesso clínico do tratamento restaurador. Objetivo: Esse estudo avaliou a resistência ao cisalhamento por extrusão (push-out) em pinos de fibra de vidro reembasados (R) ou não reembasados (NR), cimentados com cimento resinoso auto-adesivo [RelyXTM U100 (U100)] e cimento resinoso convencional [RelyXTM ARC (ARC)]. Material e método: Sessenta dentes humanos unirradiculares foram tratados endodonticamente e divididos nos grupos ARC-NR; U100-NR; ARC-R; U100-R. Os dentes foram seccionados nos terços cervical, médio e apical para serem submetidos ao teste de cisalhamento por extrusão (push-out). A resistência de união foi analisada pelo teste de Friedman; os tipos de cimento e de pinos foram comparados pelo teste de Mann Whitney. O padrão de falhas foi avaliado com câmera digital através de imagens em 200x de ampliação e foi classificado como falhas adesivas (na interface cimento/dentina ou cimento/pino), coesivas (cimento ou pino), e mistas. Resultado: No grupo ARC-NR, os valores de resistência de união foram maiores no terço cervical; os grupos U100-NR e ARC-R foram semelhantes entre os terços. No grupo U100-R, os valores de resistência de união foram semelhantes nos terços cervical e médio, e houve menor valor no terço apical. Para pinos de fibra de vidro não reembasados, a média mais alta dos valores de resistência de união foi com cimento resinoso auto-adesivo. Considera-se ainda que os pinos reembasados com cimento resinoso convencional tiveram camada de cimento mais forte em comparação com os pinos de fibra não reembasados. Conclusão: A técnica do pino reembasado foi eficiente no grupo ARC-R. Os grupos ARC-NR e U100-R mostraram melhor resistência de união na região cervical das paredes do canal radicular. As principais falhas foram adesivas na interface cimento-pino.


Subject(s)
Post and Core Technique , Dental Bonding , Shear Strength , Dental Materials , Dentin , Statistics, Nonparametric , Resin Cements
9.
RGO (Porto Alegre) ; 64(2): 140-147, Apr.-June 2016. tab, graf
Article in English | LILACS | ID: lil-789123

ABSTRACT

ABSTRACT Objective This study evaluated the shear bond strength (SBS) of lithium disilicate glass (LDG) ceramic bonded to a zirconia (Y-TZP), using different cementation strategies. Methods LDG ceramic cylinders were cemented to Y-TZP structure according to the following adhesive system (AS)/resin cement (RC) (n = 15): U- self-adhesive dual-cure RC; AMBAR- AS containing phosphate monomers (PM) + dual-cure RC; group SBU: PM+Silane/AS + light-cure RC; group ALLB: PM/AS + dual-cure RC. Specimens were subjected to SBS in a universal testing machine (0.5 mm/min). Data (MPa) were subjected to one-way ANOVA and Tukey's test (α = 0,05). Results The groups SBU and ALLB had significantly higher SBS than those provided by the group U, in which the lowest values were observed. For the AMBAR group, intermediate SBS values were found, which did not differ significantly from the values observed in the other groups. Conclusion Regardless of resins cement, the use of adhesives containing phosphate monomers provided superior bond strength than self-adhesive cement.


RESUMO Objetivo Avaliar a resistência de união por cisalhamento (RU) de uma cerâmica de dissilicato de lítio (CDL) à zircônia (Y-TZP) utilizando diferentes estratégias de cimentação. Métodos Cilindros de CDL foram cimentados à estrutura de Y-TZP de acordo com os seguintes sistemas adesivos (SA)/ Cimentos resinosos (CR) (n=15): U: CR autoadesivo de cura dual; AMBAR: SA contendo monômeros fosfatados (MF) + CR convencional de cura dual; SBU: SA contendo MF/silano + RC de cura fotoativada; ALLB: SA contendo MF/silano + CR de cura dual. Os corpos de prova foram submetidos ao teste de cisalhamento em máquina universal de ensaios (0.5 mm/min). Os dados (MPa) foram submetidos a ANOVA a um critério e teste de Tukey (α = 0,05). Resultados Observou-se que os grupos SBU e ALLB promoveram valores de RU estatisticamente superiores ao grupo U, no qual observou-se a menor média de RU. Para o grupo AMBAR, valores de RU intermediários foram encontrados, os quais não diferiram dos demais grupos. Conclusão Independente do cimento resinoso, o uso de sistemas adesivos contendo monômeros fosfatados em sua composição promoveram resistência de união superior ao cimento resinoso autoadesivo.

10.
ImplantNewsPerio ; 1(3): 511-519, abr.-mai. 2016. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-847606

ABSTRACT

Objetivo: avaliar o comportamento de diferentes materiais de moldagem na transferência de implantes a partir de um modelo padrão, utilizando-se moldeira fechada e transferentes cônicos. Material e métodos: um modelo em alumínio recebeu três implantes paralelos entre si (A, B e C), e os grupos foram divididos em: hidrocoloide irreversível, poliéter, silicone de condensação e silicone de adição. Todas as moldagens foram feitas com transferentes cônicos e moldeira fechada. As distâncias entre os implantes foram medidas com uma máquina tridimensional de medição por coordenadas (Sheffield) e, com o auxílio de um software específico, foram obtidas as medidas. A precisão entre o modelo padrão e os modelos de gesso foi verificada pelos coeficientes de correlação intraclasse, análises de variância e teste de Dunnett (nível de significância de 5%). Resultados: não houve diferença estatística entre os materiais de moldagem para as distâncias horizontais AB e BC. Entretanto, o uso do hidrocoloide irreversível resultou em maior movimentação anteroposterior em relação ao modelo-mestre, embora excelente replicabilidade tenha sido observada em todos os modelos obtidos. As perpendicularidades de A, mensuradas nos modelos obtidos a partir de moldagens realizadas com poliéter, silicone de condensação e de adição, foram significativamente menores em relação ao modelo padrão (p < 0,001). Conclusão: nas condições estudadas, o hidrocoloide irreversível deve ser evitado em moldagens para transferência de implantes.


Objective: to evaluate the behavior of different impression materials on dental implant transferring using a standard model, closed impression trays, and conical transfer copings. Material and methods: an aluminum model received three parallel implants (A, B and C), and groups were divided into: irreversible hydrocolloid, polyether, condensation, and addition silicones. All impressions were made using conical transfer copings with the closed tray technique. The inter-implant distances were measured with a three-dimensional coordinate measuring machine (Sheffield), and data collected with specific software. The accuracy between the standard and gypsum models was verifi ed by intraclass correlation coefficients, Anova, and the Dunnett test (5% level of signifi cance). Results: there was no statistical difference between the impression materials in relation to horizontal distances AB and BC. However, the use of irreversible hydrocolloid resulted in greater anteroposterior movement in relation to the master model, although excellent repeatability was observed in all the models obtained. The A perpendicularity obtained from polyether, condensation, and addition silicone materials was significantly lower in relation to the standard model (p < 0.001). Conclusion: in the studied conditions, the irreversible hydrocolloid teste here should be avoided for dental implant transferring procedures.


Subject(s)
Humans , Dental Implantation, Endosseous , Dental Implants , Dental Impression Materials , Dental Impression Technique , Dental Materials , Dental Prosthesis
11.
Braz. dent. sci ; 19(1): 106-112, 2016. tab
Article in English | LILACS, BBO | ID: lil-785290

ABSTRACT

Objetivo: o objetivo deste estudo foi avaliar a eficácia da desinfecção do gesso odontológico tipo III com usode hipoclorito de sódio 1% e ácido peracético 0,25% em diferentes tempos (1, 5 e 10 min). Material e Métodos: matrizes de silicone foram previamente contaminadas com solução contendo Bacillus subtilis por 15 min. Gesso odontológico tipo III (Herodent, Vigodent COLTÈNE SA, Rio de Janeiro, Brasil) foi inserido nas matrizes, obtendo-se espécimes contaminados. Uma matriz estéril foi utilizada para obter corpos de prova livres de contaminação. Além do controle positivo e negativo, os espécimes foramdivididos nos seguintes grupos: blocos imersos em solução salina por 1, 5 ou 10 min; blocos imersos em hipoclorito de sódio 1% por 1, 5 ou 10 min; blocosimersos em ácido peracético 0,25% por 1, 5 ou 10 min. Foi realizado plaqueamento de todos os grupos e incubados por 24 horas a 37˚C. Resultados: os resultados foram expressos por meio das contagens das unidades formadoras de colônias (UFC/ml) e os dados foram submetidos aos testes de Kruskal-Wallis seguido pelo de Dunn. Os resultados mostraram que a imersão em hipoclorito de sódio 1% e em ácido peracético 0,25% resultou em completa desinfecção dos corpos de prova em todos os tempos testados (p<0,01), enquanto que a imersão em solução salina não proporcionou efetiva desinfecção em nenhum dos tempos testados. Conclusão: pode-se concluir que houve eficácia do hipoclorito de sódio 1% e do ácido peracético 0,25% ao imergir o gesso odontológico tipo III em qualquer dos tempos de avaliação.


Objective: the purpose of this study was to evaluate the efficacy of disinfection of type III dental stone by immersion in 1% sodium hypochlorite and 0.25% peracetic acid at different periods of time (1, 5 and 10 min). Material and Methods: silicon dies were previously infected with strains of Bacillus subtilis for 15 min. Then, type III gypsum stone (Herodent, Vigodent COLTÈNE SA, Rio de Janeiro, Brazil) was inserted into the cavities to obtain contaminated specimens. A sterile silicone die was used to obtain uncontaminated specimens. The specimens were separated into positive and negative control groups, and further divided into the following groups: blocks immersed in sterile physiologic solution for 1, 5 or 10 min; blocks immersed in 1% sodium hypochlorite for 1, 5 or 10 min; and blocks immersed in 0.25% peracetic acid for 1, 5 or 10 min. All the groups were double-plated and incubated at 37˚C for 24 h. Results: the results were expressed in colony forming units (CFU/ml) and the data were submitted to the Kruskal-Wallis test followed by Dunn’s test. The results showed that immersion in 1% sodium hypochlorite and 0.25% peracetic acid resulted in complete disinfection of the test specimens at all test periods (p <0.01), whereas immersion in saline did not provide effective disinfection. Conclusion: it can be concluded that both 1% sodium hypochlorite and 0.25% peracetic acid provided effective disinfection in dental stone specimens immersed in the solutions described above, at different periods of time


Subject(s)
Calcium Sulfate , Disinfection , Peracetic Acid , Sodium Hypochlorite
12.
RGO (Porto Alegre) ; 63(4): 397-404, Oct.-Dec. 2015. tab
Article in English | LILACS-Express | LILACS | ID: lil-770574

ABSTRACT

Objective: To evaluate the effect of aging in a hard denture reline (New Truliner) and an acrylic resin (Classic) after chemical and mechanical polishing. Methods: Eighty specimens were made, divided randomly between 8 groups: G1.Acrylic Resin Classic (RAC)/Mechanical Polishing (PM); G2.RAC/PM + thermocycling (TR); G3) RAC/Chemical Polishing (PQ); G4.RAC/PQ + TR; G5.New Truliner (NT)/PM; G6.NT/PM + TR; G7. NT/PQ; G8.NT/PQ + TR. The surface hardness was measured before and after polishing, and after TR. The impact resistance tests were measured after all applied treatments. The data were submitted to ANOVA and Tukey test (a=5%). Results: Regardless of the polishing, it was noted that RAC presented significantly higher surface hardness than NT; PM had higher hardness in both materials compared with PQ; on both polishing, the impact resistance of the RAC was higher than NT. Independently of TR test, the impact resistance of the materials that received PQ was higher than received PM. The PQ caused greater changes in properties than the PM. Conclusion: Aging and chemical and mechanical polishing influenced the physical and mechanical properties of hard denture reline and acrylic resin.


Objetivo: Avaliar o efeito da termociclagem em reembasador rígido para próteses totais (New Truliner) e resina acrílica (Clássico) após polimento químico e mecânico. Métodos: Foram confeccionados 80 corpos de prova, divididos de forma randomizada entre 8 grupos: G1. Resina Acrílica Clássico (RAC)/Polimento mecânico (PM); G2. RAC/PM + termociclagem (TR); G3.RAC/Polimento químico (PQ); G4.RAC/PQ + TR; G5.New Truliner (NT)/PM; G6.NT/PM + TR; G7. NT/PQ; G8. NT/PQ + TR. A dureza superficial foi mensurada antes e após os polimentos, e após a TR. Os ensaios de resistência ao impacto foram mensurados após todos os tratamentos. Os dados foram submetidos à análise de variância e Tukey (a=0,05). Resultados: Independente do polimento verificou-se que RAC apresentou resultados de dureza superficial significativamente mais altos que NT; PM gerou superfícies mais duras em ambos os materiais quando comparado ao PQ; em ambos os polimentos, os valores de resistência ao impacto da RAC foram maiores que os do NT. Independentemente da realização da TR, a resistência ao impacto dos materiais que receberam PQ foi maior que a dos que receberam PM. PQ causou maior alteração nas propriedades do que PM. Conclusão: A termociclagem e os polimentos químico e mecânico influenciam as propriedades físicas e mecânicas do reembasador rígido e da resina acrílica.

13.
PróteseNews ; 2(4): 452-458, out.-dez. 2015. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-846764

ABSTRACT

Objetivo: este estudo avaliou a resistência à fratura de facetas confeccionadas sobre dois tipos de preparo. Métodos: utilizando-se dentes bovinos, dois grupos foram preparados: grupo I (redução incisal de 1 mm) e grupo II (redução incisal de 3 mm). Facetas laminadas foram enceradas sobre preparos dentais e confeccionadas em cerâmica IPS e.max (Ivoclar Vivadent). As superfícies internas das facetas foram tratadas com ácido fluorídrico a 10% durante 20 segundos e silanizadas. A superfície preparada do dente foi condicionada durante 15 segundos com ácido fosfórico a 37%, lavada abundantemente e secada levemente. O adesivo foi aplicado em duas camadas: dente e lado interno do laminado. A cimentação foi realizada com cimento resinoso fotopolimerizável sob pressão digital, e uma máquina de teste tipo pendular foi utilizada para simular o impacto no corpo-de-prova. Resultados: os dados de energia absorvida na fratura pelas facetas laminadas foram submetidos ao teste t de Student para amostras independentes (α = 5%), que demonstrou não haver diferença significativa entre os grupos com redução incisal de 1 mm e redução incisal de 3 mm (p=0,724). Observou-se, no grupo I, 10% das facetas laminadas com perda total, 30% extensa, mas parcial, e 60% parcial. Já no grupo II, 0% das facetas laminadas com perda total, 10% extensa, mas parcial, e 90% parcial. Conclusão: embora não tenha sido demonstradas diferenças na energia absorvida entre os dois tipos de preparo, o modo de fratura nos preparos com redução incisal de 3 mm foi mais favorável.


Objective: to evaluate the fracture resistance of laminate veneers on two preparation types. Methods: two groups were made based on bovine teeth: group I (1 mm incisal reduction) and group II (3 mm incisal reduction). All Laminate veneers were waxed over tooth preparations and fabricated with the IPS e.max ceramic (Ivoclar Vivadent). Their inner surfaces were treated with 10% hydrofluoric acid for 20 seconds and received a silane agent. The tooth surface was conditioned with 37% phosphoric acid, washed, and slightly dried. The adhesive was applied at the tooth and the laminate veneer. A photo-cured luting agent was used under fi nger pressure, and the samples were placed in an impact machine test. The fracture energy data was submitted to the Student´s t test for independent samples (5% significance level). Results: no statistical difference was observed (p = 0.724). At group I, 10% of the laminates demonstrated complete loss, 30% extensive but partial loss, and 60% partial loss. For group II, the figures were 0% for complete loss, 10% extensive but partial, and 90% partial. Conclusion: although no diff erences were seen for the absorbed energy, the 3 mm incisal reduction design was the most favorable.


Subject(s)
Cattle , Ceramics , Dental Cements , Dental Porcelain , Dental Veneers , Materials Science , Resin Cements
14.
J. Health Sci. Inst ; 33(3): 223-227, July-Sept. 2015.
Article in English | LILACS | ID: biblio-2259

ABSTRACT

Objective ­ To evaluate the effect on bond strength of an acrylic resin and thermoatived resilient denture liner material with different concentrations of propolis. Methods ­ Fourty eight specimens of acrylic resin (Lucitone 550, Dentsply) were made and united with the soft liner (Coe Soft, GC America) with different concentrations of propolis: group 1 (control) ­ only Coe Soft; Group 2 ­ Coe Soft + 75 mg of propolis; Group 3 ­ Coe Soft + 150 mg of propolis, and Group 4 ­ Coe Soft + 300 mg of propolis. The union traction resistance test was performed, and the type of fracture was evaluated. The data were analyzed descriptively and by one-way ANOVA, followed by Tukey's test (p=0.05). Results ­ There was no difference between the control group and when 75 mg of propolis was added (p>0.05), while the group with 150 mg of propolis showed lower bond strength (p<0.05), However, group 4 did not differ from the others (p>0.05). Regarding the kind of fails, the control group and group 2 showed the same failures: 91.7% cohesive and 8.3% adhesive. Group 3 showed only cohesive failure, and group 4 had cohesive failures (58.4%), adhesive (8.3%) and mixed (33.3%). Conclusions ­ It can be concluded that 75 mg of propolis extract may be considered the most suitable concentration to be added in the soft denture liner, considering that the properties of soft denture liner was not changed.


Objetivo ­ Avaliar o efeito na resistência de união entre resina acrílica e reembasador resiliente de prótese termoativado com diferentes concentrações de própolis. Métodos ­ Quarenta e oito espécimes de resina acrílica (Lucitone 550, Dentsply) foram confeccionados e unidos ao reembasador resiliente (Coe Soft, GC América) com diferentes concentrações de própolis: Grupo 1 (controle) ­ apenas o Coe Soft, Grupo 2 ­ Coe Soft + 75 mg de própolis; Grupo 3 ­ Coe Soft + 150 de própolis e Grupo 4 ­ Coe Soft + 300 mg de própolis. Foi realizado o teste de resistência à tração e o tipo de fratura foi avaliado. Os dados foram analisados de forma descritiva e através de análise de variância a um critério, seguido pelo teste de Tukey (p=0,05). Resultado ­ Não houve diferença entre o grupo controle e quando 75 mg de própolis foi adicionao (p>0,05), enquanto o grupo com 150 mg de própolis mostrou menor resistência de união (p<0,05). No entanto, o grupo 4 não diferiu dos demais (p>0,05). Em relação ao tipo de falha, o grupo controle e o grupo 2 apresentaram as mesmas falhas: 91,7% coesivas e 8,3% adesivas. O grupo 3 obteve apenas falha coesiva, e o grupo 4 teve falhas coesivas (58,4%), adesivas (8,3%) e mistas (33,3%). Conclusões ­ Conclui-se que 75mg de extrato de própolis pode ser considerada a concentração mais adequada para ser adicionada ao reembasador de prótese, considerando-se que as propriedades deste reembasador resiliente de prótese não foram alteradas.

15.
RGO (Porto Alegre) ; 63(3): 257-262, July-Sept. 2015. tab, graf
Article in English | LILACS | ID: lil-765058

ABSTRACT

Objective: To investigate the biological effect of a new method to camouflage the cobalt-chromium (CoCr) metal structure of an RPD, onto which an electrostatic paint was applied.Methods: In vitro cytotoxicity of epoxy Politherm NOBAC30C (Weg Industries SA, Santa Catarina, Brazil) in combination with polished CoCr was tested by placing it in contact with cultured human fibroblasts and comparing it with polystyrene (control surface). The cells were cultured in the presence of the test surfaces for 24, 48, 72, 94 and 120 hours. The number of viable and non-viable cells was established by manual counting. The Tukey test was used to statistically analyze cell counts between the groups.Results: The results showed that cell proliferation was similar between the groups (p =0.2174). It was observed that at 24, 48 and 72 h, there was no significant increase in cell proliferation in all groups. From 96 to 120 h, an increase in cell proliferation was observed in all groups, with no significant difference between them (p>0.05).Conclusion: The epoxy paint studied showed no cytotoxicity in vitro.


Objetivos: Analisar, biologicamente, a possibilidade do uso de pintura por aplicação eletrostática.Métodos: Por meio de testes in vitro de citotoxicidade, comparando o comportamento da tinta epóxi Politherm 30 Nobac C (Weg Indústrias S.A, Santa Catarina, Brasil) com CoCr polido e poliestireno em contato com cultura de fibroblastos humanos. Esse teste foi realizado através de contagem de células viáveis e não viáveis em tempos de 24, 48, 72, 94 e 120 horas. Para a contagem de células viáveis foi aplicada a Análise Estatística de Tukey.Resultados: Os resultados obtidos na presente pesquisa mostraram que o comportamento de crescimento celular foi estatisticamente semelhante entre grupos (p=0,2174). Observou-se que nos tempos de 24, 48 e 72 horas, não houve aumento estatisticamente significante da proliferação celular, mantendo-se o padrão para todos os grupos estudados. A partir de 96 e 120 h observamos um aumento da proliferação celular para todos os grupos estudados, sem diferenças entre os mesmos também (p>0,05). Para os resultados de células inviáveis, aplicou-se a Análise não Paramétrica de Kruskal Wallis e o teste de Dunn, devido à baixa taxa de morte celular, sem diferença estatisticamente entre os grupos (p>0,05).Conclusão: Conclui-se, portanto, que a pintura Epóxi estudada não apresentou citotoxicidade para os testes realizados in vitro.

16.
ImplantNews ; 12(6): 813-820, nov.-dez. 2015. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-850955

ABSTRACT

Objetivo: avaliar in vitro a microinfiltração bacteriana na interface dos implantes entre os pilares tipo Ucla totalmente calcináveis e calcináveis com base pré-fabricada. Material e métodos: para este estudo, foram utilizados 20 implantes com conexão de hexágono externo, diâmetro 3,75 mm, comprimento de 11,0 mm e plataforma regular (4,1 mm): destes, em dez foram acoplados pilares protéticos fundidos a partir de peças calcináveis (nylon) por um laboratório comercial, em NiCr (grupo TC); nos demais implantes, adaptaram-se dez pilares fundidos sobre bases pré-fabricadas (cobalto-cromo), seguindo as recomendações do fabricante (grupo CM). Cada conjunto implante/pilar constituiu um corpo-de-prova. Os pilares calcináveis e os de bases pré-fabricadas foram incluídos em revestimento e, após o tempo de presa final, foram levados ao forno e fundidos em centrígufa manual com maçarico de gás e oxigênio. As peças foram desincluídas do revestimento, jateadas com óxido de alumínio 60 μm e usinadas com pedra de óxido de alumínio. Elas foram inoculadas com Escherichia coli e, em seguida, os pilares protéticos foram conectados imediatamente aos seus respectivos implantes e parafusados com torque de 32 Ncm, conforme recomendado pelo fabricante. Foram colocados em meio de cultura para observação da turvação nos períodos de um, dois, cinco, sete e 14 dias, para verificação da microinfiltração pela interface implante/pilar. Resultados: testes binominais revelaram que os pilares tipo Ucla com base pré-fabricada, em todos os tempos de análise, resultaram no turvamento de um menor número de meios de cultura. Conclusão: a microinfiltração bacteriana na interface do implante pode ser reduzida pela utilização de pilares tipo Ucla calcináveis com base pré-fabricada. Os pilares totalmente calcináveis mostraram infiltração logo nas 48 horas de teste. Uma falha na adaptação entre o implante e o pilar intermediário pode levar a falhas protéticas mecânicas e perda do tecido ósseo...


Objective: to assess the bacterial leakage at the implant-abutment interface using burnout and prefabricated UCLA abutment. Material and methods: twenty external hex implants (3.75 mm diameter, 11 mm length, regular platform 4.1 mm) were divided into two groups and received burnout abutments cast in a Ni-Cr alloy (TC = 10 samples) or Co-Cr prefabricated abutments (CM = 10 samples). An implant-abutment assembly constituted a sample. The burnout and prefabricated abutments were invested and further cast with a gas oxygen torch. After, samples were divested, sandblasted (60 μm aluminum oxide particles) and finished with appropriate aluminum oxide stones. Then, samples were inoculated with E. coli, and the prosthetic abutments fastened with a 32 Ncm torque as recommended by the manufacturer. After, the assemblies were immersed in a growth media to observe turbidity at 1, 2, 5, 7, and14 days later. Results: the binominal tests revealed lower turbidity numbers for Ucla prefabricated samples at all tested periods. Conclusion: the use of prefabricated UCLA abutments reduces the chance of leakage. In addition, burnout abutments demonstrated leakage in the first 48 hours. A lack of fit at the implant-abutment interface can lead to mechanical failures and peri-implant tissue loss due to bacterial contamination.


Subject(s)
Dental Implantation , Dental Leakage , Osseointegration , In Vitro Techniques
17.
RGO (Porto Alegre) ; 62(3): 229-234, Jul-Sep/2014. graf
Article in English | LILACS | ID: lil-732732

ABSTRACT

OBJECTIVE: Abrasion resistance of three commercial brands of acrylic resin for artificial teeth, available on the domestic market (Biotone(r), Plus(r) and Vipi Dent Artiplus(r)) was evaluated by a new methodology called "Pirassununga Method ". METHODS: The Manufacturers produced the maxillary central incisor-shaped incisal resin specimens (n=27). These were embedded in chemically activated acrylic resin in an insulated metal matrix to fabricate test specimens, which were flattened on a lathe and refined manually with sandpaper. Wear testing was conducted in an experimental machine at the Vipi dental products factory. In the "Pirassununga Method" a polished metal sphere 4.8 mm in diameter, attached to a rotary device passes over the fixed specimens in programmable cycles, under 5N pressure, using distilled water as lubricant. In each sample, the groove caused by abrasion, was analyzed in two ways: Readout under a microscope to determine the breadth and depth of the groove caused by the ball, and by laser roughness meter readout, which obtained a value Rt. RESULTS: The nonparametric Kruskal Wallis test showed no statistically significant difference between the medians of brands evaluated in the cycles performed (p = 0.936). CONCLUSION: Artiplus(r) Brand showed a lower tendency to wear than commercial brands Biotone(r) and Plus(r) Vipi Dent, with the best performance shown for the IPN polymer. .


OBJETIVO: Avaliar a resistência ao desgaste por abrasão de três marcas comerciais de dentes artificiais de resina acrílica disponíveis no mercado nacional (Biotone(r), Vipi Dent Plus(r) e Artiplus(r)) por meio de uma nova metodologia. MÉTODOS: Os corpos de prova foram produzidos pelos fabricantes, com resina incisal em forma de incisivos centrais superiores (n=27). Esses dentes foram incluídos em resina acrílica ativada quimicamente dentro de uma matriz de metal isolada para confecção dos corpos de prova, e depois aplainados em torno mecânico e refinados com lixa d'agua manualmente. O ensaio do desgaste foi realizado em uma máquina experimental presente na fábrica de produtos odontológicos Vipi. No "Método Pirassununga" uma esfera metálica polida de 4,8 mm de diâmetro presa em um dispositivo que rotaciona, passa sobre os corpos de prova que estão fixos, em ciclos que podem ser programados, e tendo água destilada como lubrificante e pressão de 5N. O sulco provocado pela abrasão em cada corpo de prova foi analisado de duas maneiras: Leitura em microscópio para determinar a largura e a profundidade do sulco provocado pela esfera e rugosímetro de leitura a laser, do qual foi obtido o valor Rt. RESULTADOS: Por meio do teste não paramétrico de Kruskal Wallis observou-se que não houve diferença estatisticamente significante entre as medianas das marcas avaliadas nos ...

18.
Clín. int. j. braz. dent ; 10(2): 156-163, abr. -jun. 2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-724747

ABSTRACT

O ajuste oclusal é uma técnica amplamente utilizada para modificar a superfície oclusal a superfície oclusal dos dentes, a fim de restabelecer o equilíbrio oclusal, articular e neuromuscular. Entretanto, sua indicação deve ser específica, considerando-se um procedimento irreversível. Nesse contexto, diversos autores têm abordado a sequência clínica para a realização do ajuste oclusal, embora o uso de diferentes nomenclaturas e técnicas torne-o um procedimento de difícil compreensão aos cirurgiões-dentistas. Assim, o objetivo desse trabalho é discutir os principais aspectos relacionados ao ajuste oclusal em dentes naturais por meio do desgaste seletivo, propondo uma abordagem simplificada da técnica, considerando-se uma avaliação funcional e dinâmica da oclusão


The occlusal adjustment is a technique widely used to modify the occlusal surface occlusal surface of the teeth in order to restore the occlusal, articular and neuromuscular equilibrium. However, its indication should be specific, considering that it is an irreversible procedure. In this context, several authors have addressed the clinical sequence to perform the occlusal adjustment, although the use of different nomenclatures and techniques makes it a difficult understand procedure to dentists. Thus, the aim of this study is to discuss the main aspects related to occlusal adjustment in natural teeth through selective grinding, proposing a simplified approach of the technique, considering a functional and dynamic occlusion assessment


Subject(s)
Centric Relation , Malocclusion , Occlusal Adjustment
19.
RGO (Porto Alegre) ; 62(2): 143-147, Apr-Jun/2014. graf
Article in English | LILACS | ID: lil-725598

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate the microhardness in pressing layers of prefabricated modified acrylic resin teeth. METHODS: Lower first molar teeth with two (Biotone(r) IPN and Bioform(r)) or three pressing layers (Artiplus(r), Trilux(r) Eurovipi, and Natusdent(r)) were hemisected in a bucco-lingual plane and embedded in a self-curing acrylic resin (n =10). Specimens were then ground flat and polished using 400, 600 and 1200 aluminium oxide paper in a rotatory polisher. In each pressing layer, microhardness was measured using a Knoop indenter in three different locations spaced 300 µm apart under a 10-g load, applied for 5 sec. RESULTS: Analysis of variance and Tukey's tests demonstrated that there was no difference in microhardness in the first layer of the teeth analyzed (p = 0.355), whereas in the second layer, the brand Artiplus(r) showed higher values when compared to the brand Natusdent(r) (p = 0.018). For the third layer, the brands Artiplus(r) and Trilux(r) Eurovipi revealed higher microhardness when compared to Natusdent(r) teeth (p < 0.001). CONCLUSION: For the outer most superficial layer of the artificial teeth, the microhardness of the different brands was similar, while differences were noted for the second and third layers among the artificial teeth, with Artiplus(r) teeth showing higher microhardness than Natusdent(r). .


OBJETIVO: Avaliar a microdureza nas camadas de prensagem de dentes fabricados em resina acrílica modificada. MÉTODOS: Primeiros molares inferiores pré-fabricados com duas (Biotone(r) IPN e Bioform(r)) ou três camadas de prensagem (Artiplus(r), Trilux(r) Eurovipi e Natusdent(r)), foram hemisseccionados no sentido vestíbulo-lingual e embutidos em resina acrílica autopolimerizável (n = 10). Os espécimes foram, então, planificados e polidos com lixas de óxido de alumínio nas granulações 400, 600 e 1200, em politriz giratória. Em cada camada de prensagem, a microdureza foi mensurada utilizando indentador Knoop em três diferentes localizações, espaçadas em 300 µm, sob carga de 10 g, aplicada por 5 s. RESULTADOS: Análises de variância e testes de Tukey demonstraram que os dentes avaliados não apresentaram diferenças de microdureza na primeira camada (p = 0,355), enquanto na segunda, os dentes da marca Artiplus(r) revelaram valores superiores em relação aos dentes da marca Natusdent(r) (p = 0,018). Na terceira camada, os dentes da marca Artiplus(r) e Trilux(r) Eurovipi apresentaram microdureza superior àquela verificada para os dentes Natusdent(r) (p < 0,001). CONCLUSÃO: Na camada externa, mais superficial, a microdureza dos dentes artificiais foi semelhante nas diferentes marcas. Apenas nas segunda e terceira camadas houve diferenças entre as marcas de dentes artificiais, sendo que os dentes da Artiplus(r) apresentaram microdureza superior aos dentes Natusdent(r). .

20.
RGO (Porto Alegre) ; 61(3): 369-374, jul.-set. 2013. ilus, tab
Article in English | LILACS | ID: lil-691753

ABSTRACT

Objective: To evaluate the shear bond strength of a feldspathic ceramic cemented to a composite resin using a resin-based cement, following different treatments to the ceramic surface. Methods: 30 ceramic samples were prepared and divided into 3 groups according to surface treatment: group 1 - control, group 2 - 10% hydrofluoric acid etching for 2 minutes, rinsing under running water and air-drying, group 3 - 10% hydrofluoric acid for 2 minutes, rinsing under running water, air-drying followed by silane. Subsequently, composite resin discs were cemented onto the ceramic specimens using a resin cement and light-curing for 40 seconds. Shear bond strength test was performed on an Emic DL2000 testing machine. Results: Statistical analysis revealed the following results: there was a significant increase in bond strength in the group etched with hydrofluoric acid when compared with the control, whilst no significance was found in the group treated with silane after etching. Conclusion: The assessment of failure types under light microscopy revealed a predominance of adhesive failures in the control group and cohesive failures in the remaining groups.


Objetivo: Avaliar a resistência ao cisalhamento de uma porcelana feldspática, submetida à diferentes tratamentos superficiais, cimentada a uma resina composta, utilizando-se um cimento resinoso. Métodos: Foram confeccionadas 30 amostras de porcelana, divididas em 3 grupos e receberam os seguintes tratamentos de superfície: Grupo1 - grupo controle; Grupo2 - tratada com ácido fluorídrico 10% por 2 minutos, lavada em água corrente e secada com jatos de ar; Grupo3 - tratada com ácido fluorídrico a 10% por 2 minutos, lavada em água corrente, secada com jatos de ar e silanizada. Na seqüência foi realizada a cimentação dos discos de resina composta na porcelana, com cimento resinoso e fotopolimerizado por 40 segundos. O teste de cisalhamento foi realizado numa máquina Emic DL2000. Resultados: Após análise estatística chegou-se aos seguintes resultados: houve um aumento significativo na resistência adesiva nos grupos que sofreram condicionamento da superfície da porcelana, em relação ao grupo controle. A aplicação do silano nas porcelanas condicionadas pelo ácido fluorídrico, não foi significante. Conclusão: Na análise das falhas em microscópio ótico, predominaram as adesivas no grupo controle, e as coesivas nos demais grupos.


Subject(s)
Resin Cements , Dental Porcelain , Composite Resins , Shear Strength